Product description

Thermocouple Converter, 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Housing width: 20 mm, Number of cha

Product Details

  • Current output
    4 ... 20 mA , limited to ≤ 35 mA
  • Control elements
    DIP switch, rotary switch
  • EU-type examination certificate
    ZELM 00 ATEX 0035
  • Voltage
    16.1 V
  • Lead resistance
    max. 100 Ω per line
  • After calibration
    0.1 % of full-scale value ± 1 K for the cold junction
  • Insulation coordination
    EN 50178
  • Supplementary information
    Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
  • Load
    (U -12 V) / 0.02 A
  • Fault signal
    downscaling ≤ 3 mA , upscaling ≥ 22 mA
  • Characteristic curve
    the output voltage is linearly proportionate to the input voltage (not to temperature)
  • Input/Output
    safe isolation according to EN 50178, rated insulation voltage 253 Veff
  • Dimensions
    20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
  • Ambient temperature
    -20 ... 60 °C (-4 ... 140 °F)
  • Maximum safe voltage
    60 V (Attention! The rated voltage can be lower.)
  • Connection side
    field side
  • Signal type
    Analog input
  • Temperature effect
    temperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at Tamb= 20 °C (68 °F))
  • Rise time
    250 ms
  • Galvanic isolation
    EN 50178
  • Marking
    Ex-HexagonII (1)GD [EEx ia] IIC
  • Control drawing
    116-0132
  • Rated voltage
    12 ... 35 V DC loop powered
  • Measurement range
    span 4 ... 100 mV, zero point -12 ... 60 mV , both adjustable
  • Labeling
    space for labeling at the front
  • Mounting
    on 35 mm DIN mounting rail acc. to EN 60715:2001
  • Connection
    terminals 1+, 2-, 3- thermocouple E, J, K, N, R, S or T, cold junction referenced to 0 °C (32 °F)
  • Directive 2014/30/EU
    EN 61326-1:2013 (industrial locations)
  • Power dissipation
    0.4 W
  • Configuration
    via DIP switches, via rotary switch
  • Mass
    approx. 150 g
  • Certificate
    TÜV 01 ATEX 1777 X
  • Current
    lead monitoring ON: ≤ 15 nA; OFF: ≤ 1 nA
  • Influence of supply voltage
    6.5 ppm/V
  • Degree of protection
    IEC 60529
  • Directive 2014/34/EU
    EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
  • Power
    3.2 mW

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



KFD0-TT-EX1 Related Documents

Manufacturer warranty

KFD0-TT-EX1 Pepperl + Fuchs

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

Your Safety, Our Priority.


Warranty

Manufacturer warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare KFD0-TT-EX1 with other Electronic Components products

Current output

Control elements

EU-type examination certi...

Voltage

Lead resistance

After calibration

Insulation coordination

Supplementary information

Load

Fault signal

Selected product

KFD0-TT-EX1
Backordered
KFD0-TT-EX1
Pepperl + Fuchs

Thermocouple Converter, 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple inpu...

Current output4 ... 20 mA , limited to ≤ 3...

Control elementsDIP switch, rotary switch

EU-type examination certificateZELM 00 ATEX 0035

Voltage16.1 V

Lead resistancemax. 100 Ω per line

After calibration0.1 % of full-scale value ± ...

Insulation coordinationEN 50178

Supplementary informationObserve the certificates, de...

Load(U -12 V) / 0.02 A

Fault signaldownscaling ≤ 3 mA , upscali...

DV-3M-24
1 in stock
DV-3M-24
Clippard

DV 3-Way Valve, Wire Leads, Manifold Mount, 24 VDC, Manifold Options: 15781-2, 15781-4, 15490-5

Current output-

Control elements-

EU-type examination certificate-

Voltage-

Lead resistance-

After calibration-

Insulation coordination-

Supplementary information-

Load-

Fault signal-

CX14NB47501W
1 in stock
CX14NB47501W
ROSS Controls

CX Series 2/2 Solenoid Valve, Normally Closed, Port (In) 1/2" NPT, Port (Out) 1/2"NPT, 24 VDC

Current output-

Control elements-

EU-type examination certificate-

Voltage-

Lead resistance-

After calibration-

Insulation coordination-

Supplementary information-

Load-

Fault signal-

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

Thermocouple Converter, 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Housing width: 20 mm, Number of cha

Similar products from: Electronic Components

What can I help you find today?

Recommended parts