KFD0-TT-EX1 Pepperl + Fuchs Electronic Components


Part#:KFD0-TT-EX1
Manufacturer:Pepperl + Fuchs
Category:Electronic Components
Product Lifecycle:Active
Product description
Thermocouple Converter, 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Housing width: 20 mm, Number of cha
Product Details
- Current output 4 ... 20 mA , limited to ≤ 35 mA
- Control elements DIP switch, rotary switch
- EU-type examination certificate ZELM 00 ATEX 0035
- Voltage 16.1 V
- Lead resistance max. 100 Ω per line
- After calibration 0.1 % of full-scale value ± 1 K for the cold junction
- Insulation coordination EN 50178
- Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
- Load (U -12 V) / 0.02 A
- Fault signal downscaling ≤ 3 mA , upscaling ≥ 22 mA
- Characteristic curve the output voltage is linearly proportionate to the input voltage (not to temperature)
- Input/Output safe isolation according to EN 50178, rated insulation voltage 253 Veff
- Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
- Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
- Maximum safe voltage 60 V (Attention! The rated voltage can be lower.)
- Connection side field side
- Signal type Analog input
- Temperature effect temperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at Tamb= 20 °C (68 °F))
- Rise time 250 ms
- Galvanic isolation EN 50178
- Marking
II (1)GD [EEx ia] IIC - Control drawing 116-0132
- Rated voltage 12 ... 35 V DC loop powered
- Measurement range span 4 ... 100 mV, zero point -12 ... 60 mV , both adjustable
- Labeling space for labeling at the front
- Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
- Connection terminals 1+, 2-, 3- thermocouple E, J, K, N, R, S or T, cold junction referenced to 0 °C (32 °F)
- Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
- Power dissipation 0.4 W
- Configuration via DIP switches, via rotary switch
- Mass approx. 150 g
- Certificate TÜV 01 ATEX 1777 X
- Current lead monitoring ON: ≤ 15 nA; OFF: ≤ 1 nA
- Influence of supply voltage 6.5 ppm/V
- Degree of protection IEC 60529
- Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
- Power 3.2 mW
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
KFD0-TT-EX1 Related Documents
Similar products from: Pepperl + Fuchs Electronic Components
Manufacturer warranty
KFD0-TT-EX1 Pepperl + Fuchs
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
We deliver nationwide and international
Secure Payment Processing
Your Safety, Our Priority.
Warranty
Manufacturer warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare KFD0-TT-EX1 with other Electronic Components products
Current output
Control elements
EU-type examination certi...
Voltage
Lead resistance
After calibration
Insulation coordination
Supplementary information
Load
Fault signal
Selected product

KFD0-TT-EX1
Pepperl + Fuchs
Thermocouple Converter, 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple inpu...
Current output4 ... 20 mA , limited to ≤ 3...
Control elementsDIP switch, rotary switch
EU-type examination certificateZELM 00 ATEX 0035
Voltage16.1 V
Lead resistancemax. 100 Ω per line
After calibration0.1 % of full-scale value ± ...
Insulation coordinationEN 50178
Supplementary informationObserve the certificates, de...
Load(U -12 V) / 0.02 A
Fault signaldownscaling ≤ 3 mA , upscali...
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Thermocouple Converter, 1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Housing width: 20 mm, Number of cha
Similar products from: Electronic Components
What can I help you find today?