SRB200X2 Schmersal Electronic Components


Part#:SRB200X2
Alt. Part#:101181911
Manufacturer:Schmersal
Category:Electronic Components
Product Lifecycle:Active
Product description
Safety-monitoring modules; Stop category 0; 2 safety contacts, STOP 0; Suitable for the signal processing of outputs with contact sensors
Product Details
- Stop-Category 0
- Number of LEDs 3
- Tightening torque of Clips 0.6 Nm
- Rated impulse withstand voltage Uimp 4 kV
- Rated AC voltage for controls, 60 Hz, minimum 20.4 VAC
- ON delay at automatic start Adjustable
- Switching capacity, minimum 10 VDC
- Material of the contacts, electrical AgSn0. self-cleaning, positive drive
- Short-circuit recognition Yes
- Mechanical life, minimum 10,000,000 Operations
- Depth 121 mm
- Ambient temperature, maximum +60 °C
- Rated AC voltage for controls, 50 Hz, minimum 20.4 VAC
- Note (Contact resistance) in new state
- Voltage, Utilisation category AC15 250 VAC
- Wire breakage detection Yes
- Number of openers 2
- Number of safety contacts 2
- Cable section, maximum 2.5 mm²
- Storage and transport temperature, minimum -40 °C
- Rated operating voltage 24 VAC -15% / +10%, 24 VDC -15%/+20%, residual ripple max. 10%
- Contact resistance, maximum 0.1 Ω
- Standards IEC 61508, IEC/EN 60204-1, EN 60947-5-1
- Mounting Snaps onto standard DIN rail to EN 60715
- Height 100 mm
- Overvoltage category III
- Rated control voltage at DC, maximum 28.8 VDC
- Electrical power consumption 3 VA
- Pull-in delay at RESET, typically 20 ms
- Switching capacity, maximum 250 VAC
- Electronic Fuse Yes
- Start input Yes
- Terminal Connector Screw connection, rigid or flexible
- Width 22.5 mm
- Storage and transport temperature, maximum +85 °C
- Degree of pollution to IEC/EN 60664-1 2
- Current, Utilisation category AC-15 6 A
- Conduction resistance, maximum 40 Ω
- Enclosure material Glass-fibre reinforced thermoplastic, ventilated
- Earth connection detection Yes
- Cable section, minimum 0.25 mm²
- Degree of protection of the mounting space IP54
- Restistance to shock 30 g / 11 ms
- Rated control voltage at AC 60 Hz, maximum 26.4 VAC
- Drop-out delay in case of power failure, typically 80 ms
- Voltage, Utilisation category DC13 24 VDC
- EMC rating EMC-Directive
- Climatic stress EN 60068-2-78
- Reset edge detection Yes
- Terminal designations IEC/EN 60947-1
- Ambient temperature, minimum -25 °C
- Resistance to vibrations to EN 60068-2-6 10 ... 55 Hz, Amplitude 0.35 mm
- Rated control voltage at AC 50 Hz, maximum 26.4 VAC
- Drop-out delay in case of emergency, typically 20 ms
- Current, Utilisation category DC13 6 A
- Gross weight 230 g
- Feedback circuit Yes
- Integral System Diagnostics, status Yes
- Degree of protection of the enclosure IP40
- Degree of protection of clips or terminals IP20
- Frequency range 50 Hz, 60 Hz
- Rated AC voltage for controls at DC minimum 20.4 VDC
- Pull-in delay at automatic start, maximum, typically 100 ms
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
SRB200X2 Related Documents
Manufacturer warranty
SRB200X2 Schmersal
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
We deliver nationwide and international
Secure Payment Processing
Your Safety, Our Priority.
Warranty
Manufacturer warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
About the manufacturer
Applied Automation is an authorized Schmersal distributor, proudly offering a diverse range of innovative safety and automation solutions tailored to meet the rigorous demands of modern industries. Schmersal is a globally renowned manufacturer specializing in the development and production of high-quality safety systems designed to protect both personnel and machinery across various industrial sec...
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Safety-monitoring modules; Stop category 0; 2 safety contacts, STOP 0; Suitable for the signal processing of outputs with contact sensors