Inductive sensor, Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Construction type: VariKont ®, Series: VariKont ®, Type of voltage: DC, Equipment protection level Ga

Product Details

  • Reduction factor rAl
    0.31
  • Switching frequency
    0 ... 150 Hz
  • Equipment protection level Ga
    IECEx PTB 11.0021X
  • Equipment protection level Gb
    IECEx PTB 11.0021X
  • Minimum core cross-section
    without wire end ferrule 0.5 mm2, with connector sleeves 0.34 mm2
  • Use in the hazardous area
    see instruction manuals
  • Switching function
    Normally closed (NC)
  • Measuring plate not detected
    min. 2.2 mA
  • Standards
    EN 60947-5-2:2007, EN 60947-5-2/A1:2012, IEC 60947-5-2:2007, IEC 60947-5-2 AMD 1:2012
  • Hazardous Location
    E501628
  • Core cross section
    up to 2.5 mm2
  • Reduction factor rCu
    0.3
  • Short-circuit protection
    yes
  • EAC conformity
    TR CU 012/2011
  • Connection type
    screw terminals
  • Mass
    225 g
  • Assured operating distance
    0 ... 32.4 mm
  • Reverse polarity protection
    yes
  • ANZEx
    19.3001X
  • Degree of protection
    IP68 / IP69K
  • Actual operating distance
    36 ... 44 mm
  • Measuring plate detected
    ≤ 1 mA
  • Electromagnetic compatibility
    NE 21:2007
  • Storage temperature
    -40 ... 100 °C (-40 ... 212 °F)
  • Reduction factor r304
    0.74
  • Hysteresis
    typ. 5 %
  • NAMUR
    EN 60947-5-6:2000, IEC 60947-5-6:1999
  • NEPSI certificate
    GYJ16.1394X
  • Sensing face
    PA
  • Rated operating distance
    40 mm
  • MTTFd
    1415 a
  • Equipment protection level Da
    IECEx PTB 11.0021X
  • Ambient temperature
    -25 ... 100 °C (-13 ... 212 °F)
  • Output type
    NAMUR
  • Diagnostic Coverage (DC)
    0 %
  • Ordinary Location
    E87056
  • Maximum core cross-section
    without wire end ferrule 2.5 mm2, with connector sleeves 1.5 mm2
  • Installation
    non-flush
  • Switching state indicator
    LED, yellow
  • Equipment protection level Mb
    IECEx PTB 11.0021X
  • Information for connection
    A maximum of two conductors with the same core cross section may be mounted on one terminal connection!, tightening torque 1.2 Nm + 10 %
  • Note
    Tightening torque: 1.8 Nm (housing)
  • Nominal voltage
    8.2 V (Riapprox. 1 kΩ)
  • Mission Time (TM)
    20 a
  • Control drawing
    116-0451
  • Housing material
    PA

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



NBN40-U2K-N0 Related Documents

Manufacturer warranty

NBN40-U2K-N0 Pepperl + Fuchs

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

Your Safety, Our Priority.


Warranty

Manufacturer warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare NBN40-U2K-N0 with other Electronic Components products

Reduction factor rAl

Switching frequency

Equipment protection leve...

Equipment protection leve...

Minimum core cross-sectio...

Use in the hazardous area

Switching function

Measuring plate not detec...

Standards

Hazardous Location

Selected product

NBN40-U2K-N0
Backordered
NBN40-U2K-N0
Pepperl + Fuchs

Inductive sensor, Extended temperature range, Switching function: Normally closed (NC), Output type:...

Reduction factor rAl0.31

Switching frequency0 ... 150 Hz

Equipment protection level GaIECEx PTB 11.0021X

Equipment protection level GbIECEx PTB 11.0021X

Minimum core cross-sectionwithout wire end ferrule 0.5...

Use in the hazardous areasee instruction manuals

Switching functionNormally closed (NC)

Measuring plate not detectedmin. 2.2 mA

StandardsEN 60947-5-2:2007, EN 60947-...

Hazardous LocationE501628

NBN4-12GM50-E0-V1
2 in stock
NBN4-12GM50-E0-V1
Pepperl + Fuchs

Inductive sensor, Extended temperature range, Switching function: Normally open (NO), Output type: N...

Reduction factor rAl0.47

Switching frequency0 ... 2650 Hz

Equipment protection level Ga-

Equipment protection level Gb-

Minimum core cross-section-

Use in the hazardous area-

Switching functionNormally open (NO)

Measuring plate not detected-

Standards-

Hazardous Location-

NBB2-12GM50-E2-V1
3 in stock
NBB2-12GM50-E2-V1
Pepperl + Fuchs

Inductive sensor, Extended temperature range, Switching function: Normally open (NO), Output type: P...

Reduction factor rAl0.29

Switching frequency0 ... 3500 Hz

Equipment protection level Ga-

Equipment protection level Gb-

Minimum core cross-section-

Use in the hazardous area-

Switching functionNormally open (NO)

Measuring plate not detected-

Standards-

Hazardous Location-

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

Inductive sensor, Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Construction type: VariKont ®, Series: VariKont ®, Type of voltage: DC, Equipment protection level Ga

Similar products from: Electronic Components

What can I help you find today?

Recommended parts